|
|
3
|
Sector
|
Security Services Tenders
|
Tender Value
|
N.A.
|
Location
|
Delhi Tenders
|
Ref.No
|
55908870
|
Closing Date
|
20 - Mar - 2023
|
45 Days to go
|
View Tender Details
|
|
Procurement of spares for mig-29 aircraft, shutter, transformer, switch fuel level jet type, filter, rail stack, fuel shut off valve, iff transponder (tsc2525), ehd for sos, ehd for sos, antenna gps/glonass, relay, shock mount ses4am-4, connector, connector, rotor, accepting assembly of ventral tank, connecting pipe, bracket, button, attachment to pdo-1, bell crank, time relay, timing relay, selector switch, rod set of assembly part’s, control assembly ni the central part of frame 7, bracket, set of assembly parts 250, block, terminal, flowmeter module , high-frequency amplifier unit (units 1-1), board.
|
|
|
|
5
|
Sector
|
Municipal Corporations Tenders
|
Tender Value
|
5.50 Lakh
|
Location
|
Delhi Tenders
|
Ref.No
|
56625571
|
Closing Date
|
04 - Mar - 2023
|
29 Days to go
|
View Tender Details
|
|
Comprehensive annual maintenance contract for data center equipments #*. (server, storage, kvm switches, juniper switches/firewall, load balancer, cisco switches, cisco routers, cisco san switches, ups, air conditioning, safety and security systems, network infrastructure passive components) and other peripheralis.
|
|
|
6
|
Sector
|
Air Transport Tenders
|
Tender Value
|
N.A.
|
Location
|
Delhi Tenders
|
Ref.No
|
56344067
|
Closing Date
|
22 - Feb - 2023
|
19 Days to go
|
View Tender Details
|
|
Supply of design, supply, installation, testing and commissioning (dsitc) of grid connected ground mounted dc solar pv-module-based power supply system of capacity below mentioned with modules fixed in anodized aluminium frame complete as required including elevated structural support systems for all components after proper soil investigation / treatment as per site conditions, modular inverters with atleast 25 percent standby / spare capacity with required communication / data / control / power cables, safety system for reverse power protection, min ip65 rated dc db / jb for connection of modules to inverters . . . . . . solar power plant complete as required and as per technical specifications and other terms and conditions of the contract. it also includes provision of skilled / unskilled manpower as per the requirement (as and when required) for proper operation and routine maintenance of the said solar power plant during defects liability period (dlp) of 02 years as per specifications, terms and conditions of the tender document., it also includes o and aicmc of above said solar power plant for 08 years after expiry of dlp of 02 years as per tender specifications, terms and conditions etc. completed as required., note -, the quoted rates are inclusive of 08 years of operation and aicmc cost (after dlp period of 02 years). the share of o and aicmc and dsitc components are fixed. the o and aicmc component shall be 10 percent of quoted amount and dsitc component shall be 90 percent of the quoted amount., distribution of 10 percent . . . . . ., location - udaipur airport , capacity - 500 kw (ac), approx. distance of evacuation point from solar installation - 2.5 km, evacuation point voltage level - 33 kv (as per system design and site requirement), note - for details refer tender document schedule of quanties page soq 1", "design supply, installation, testing and commissioning (dsitc) of grid connected ground mounted dc solar pv-module-based power supply system of capacity below mentioned with modules fixed in anodized aluminium frame complete as required including elevated structural support systems for all components after proper soil investigation / treatment as per site conditions, modular inverters with atleast 25 percent standby / spare capacity with required communication / data / control / power cables, safety system for reverse power protection, min ip65 rated dc db / jb for connection of modules to inverters . . . . . . solar power plant complete as required and as per technical specifications and other terms and conditions of the contract. it also includes provision of skilled / unskilled manpower as per the requirement (as and when required) for proper operation and routine maintenance of the said solar power plant during defects liability period (dlp) of 02 years as per specifications, terms and conditions of the tender document., it also includes o and aicmc of above said solar power plant for 08 years after expiry of dlp of 02 years as per tender specifications, terms and conditions etc. completed as required., note , the quoted rates are inclusive of 08 years of operation and aicmc cost (after dlp period of 02 years). the share of o and aicmc and dsitc components are fixed. the o and aicmc component shall be 10 percent of quoted amount and dsitc component shall be 90 percent of the quoted amount., distribution of 10 percent . . . . . , location - jabalpur airport , capacity - 500 kw (ac), approx. distance of evacuation point from solar installation - 0.5 km, evacuation point voltage level - ht / lt (as per system design and site requirement), note - for details refer tender document schedule of quanties page soq 2", "design supply, installation, testing and commissioning (dsitc) of grid connected ground mounted dc solar pv-module-based power supply system of capacity below mentioned with modules fixed in anodized aluminium frame complete as required including elevated structural support systems for all components after proper soil investigation / treatment as per site conditions, modular inverters with atleast 25 percent standby / spare capacity with required communication / data / control / power cables, safety system for reverse power protection, min ip65 rated dc db / jb for connection of modules to inverters . . . . . . . solar power plant complete as required and as per technical specifications and other terms and conditions of the contract. it also includes provision of skilled / unskilled manpower as per the requirement (as and when required) for proper operation and routine maintenance of the said solar power plant during defects liability period (dlp) of 02 years as per specifications, terms and conditions of the tender document., it also includes o and aicmc of above said solar power plant for 08 years after expiry of dlp of 02 years as per tender specifications, terms and conditions etc. completed as required., note -, the quoted rates ar
|
|
|
|
|
|
|